Most candidates can name a straight beam and an angle beam. They lose marks when the stem describes a part and a flaw and asks which beam, from where, and why that position.
Beam technique questions are choices, and each choice has a geometric reason behind it.
ASNT UT II — The ASNT Level II ultrasonic exam in sixty seconds. Watch on YouTube · CertCrafter What does ASNT list for beam techniques?
Less than a textbook chapter, and enough to plan around. The examination page gives the UT General exam as 50 items in 2 hours. It publishes no percentages for any heading, so a weighting from another site is an estimate. Our certification guide explains how the central route differs from employer certification.
The outline for exams before February 5, 2027 hides techniques in broad headings: Review of Ultrasonic Techniques, Evaluation of Weldments and Evaluation of Bonded Structures. After that date, the verbs get specific. A technician performs UT exams for inherent, manufacturing and in-service discontinuities, with the examples written as zero-degree, angle beam, pulse echo and through transmission.
Our question banks file this area as Straight Beam, Angle Beam and Specialised Methods. That is our label, not an ASNT heading. The 2027 outline guide walks the change group by group.
When do you use a straight beam, and when an angle beam?
Match the beam to the way the flaw is oriented. A straight beam travels normal to the surface, so it likes flaws that lie parallel to it: laminations, and wall thickness work. An angle beam enters the steel as a shear wave at a chosen angle, so it likes flaws that stand up across the beam, such as cracks and lack of fusion in a weld.
The weld is the classic case. You cannot scan a butt weld from the top, because the cap is in the way. So the probe sits on the plate beside the weld and the sound arrives from the side, at an angle. The UT physics guide covers the refraction behind that angle.
On a job, the technique is already chosen for you. The procedure names the probe, the angle and the scan plan, and the Level II applies it. The exam asks whether you understand why those choices were made.
Why is a weld root scanned at half skip?
Because the root is where the far surface meets the face of the joint, and at half skip the beam hits that corner on its first leg. Two surfaces at right angles form a corner trap, and a corner trap throws energy straight back along the way it came. That is why lack of penetration and root cracks light up so strongly.
One of our free questions asks for the technical reason a procedure requires half skip on a single-sided root with an angle beam probe. The distractors are tempting. The shorter path means less attenuation, which is true but is a side benefit. The near field is a property of the probe, not of the leg. Mode conversion happens at the far surface, but avoiding it is not the point. The corner trap is the answer.
Worked example: where does the probe sit for the root?
A single-V butt weld is welded from one side. The procedure calls for a shear wave probe at a stated angle and half skip on the root.
- Half skip means the beam reaches the far surface once, at the root. So the sound has travelled the full plate thickness, and the depth at that point equals the thickness.
- Surface distance equals depth times the tangent of the probe angle.
- Multiply the plate thickness by that tangent. The result is the distance along the surface from the probe’s exit point to the spot directly above the root.
- Full skip puts the beam back at the top surface at twice that distance, so the root is not at full skip.
- Set the probe so its exit point sits that distance from the root line. Measure from the exit point, not from the front of the wedge.
The last step is the usual slip. A stem may give the distance from the front of the wedge and ask for the exit point. Read what is measured from where.
The Complete Exam Kit works more of these under timed conditions, with every answer explained.
How do you test a bonded panel?
With through transmission, not pulse echo. Picture an aluminium honeycomb panel with thin epoxy skins that has to be checked for disbonds.
In pulse echo, a thin facesheet rings. The multiples from it crowd the part of the timebase where the bond line signal would sit. Through transmission avoids the problem: one probe sends from one face, the other receives on the opposite face, and the measurement is how much energy gets across. A disbond or a crushed core blocks the path and shows as a drop in transmitted amplitude.
Another of our free questions tests this, and its wrong options are plausible. A shear wave probe on the skin sounds clever, but shear waves are attenuated in adhesives and do not couple into an air-filled core. A longer delay line moves the interface echo and leaves the facesheet ringing. Gating a third back wall echo assumes clean multiples through a panel that barely returns a first one.
What do crews get wrong with beam technique in the field?
They scan the wrong leg. A flaw seen on the second leg is a different depth and a different surface distance from the same indication on the first leg, and a tired technician logs the wrong one. Marking the scan lines on the plate before the first pass costs a minute and saves a re-shoot.
They also trust a single angle on a weld with a flaw that does not face the beam. A crack tilted away from the beam can return almost nothing. This is why procedures name more than one angle, and why a limitation, such as a support saddle covering part of a seam, belongs in the report.
How do candidates lose marks in this domain?
First, by picking the true statement that is not the reason. Shorter paths do lose less energy, but the exam asks why half skip, and the answer is the corner.
Second, by measuring from the wrong point. Surface distance runs from the exit point.
Third, by reaching for pulse echo out of habit. When the facesheet rings, the technique has to change.
Fourth, by treating gain as a fix. Raising it lifts noise and signal together.
How should you study it?
Sketch each technique once with a part, a flaw orientation and the beam path. Then say aloud why that beam suits that flaw. Try the free ten-question sample and read every explanation, including the ones you got right. The equipment and calibration guide covers the probes that go with these techniques, and the study guides hub lists the rest. Our channel also has a short video: the ASNT Level II ultrasonic exam in sixty seconds.
Tonight, draw a one-sided butt weld, mark half skip and full skip, and check where the root falls.
Comments