ASME GDTP Rules and Symbology: Terms People Mix Up

By Sandeep Bandyopadhyay, Senior aerospace engineer · PMP, MBA, Six Sigma

TL;DR

Most lost marks in the ASME GDTP Technologist rules and symbology section come from look-alike terms: a datum plane against a datum axis, profile of a line against profile of a surface, a whole-face flatness limit against a per unit one, and runout against a diameter. This page sets each pair side by side with the shop-floor consequence and the exam trap. The exam is 150 questions in 4 hours, closed book.

Original questions, not exam dumps. Every CertCrafter question is written from the published body of knowledge and the referenced codes. None is copied from a live exam, and CertCrafter is independent: not affiliated with or endorsed by any awarding body.

A coloured engineering drawing of a safety valve from 1845
Photo: Engineering; a safety valve. Coloured drawing, 1845. Wellcome V0024661 by Unknown (Wikimedia Commons), CC BY 4.0, via Wikimedia Commons.

Two callouts can look nearly identical on a drawing and ask for completely different parts. The ASME GDTP Technologist exam knows this. Its rules, definitions and symbology section is worth 25% of the mark, and a good share of its questions turn on one word of a stem.

This page lines up the term pairs people mix up, says what each one means on a real job, and shows where the exam hides the slip.

Which GD&T terms do candidates mix up most?

ASME says the Technologist level tests the rules, definitions, principles and meanings of the symbols and modifiers, the functions and relationships of part features and geometric controls, and the calculations that come off a drawing. That is a vocabulary exam with arithmetic attached.

The exam is 150 questions in 4 hours, closed book. You pass at 74% with at least 50% in every section. Our video on datum features, reference frames and targets covers the first pair below in motion.

Video: GD&T Datums Explained: Datum Features, Reference Frames and Targets (ASME GDTP Y14.5-2018) GD&T Datums Explained: Datum Features, Reference Frames and Targets (ASME GDTP Y14.5-2018) Watch on YouTube · CertCrafter
Image: video thumbnail, source: CertCrafter on YouTube (@certcrafters).

Here is the short version, before the detail.

Pair What separates them What the exam does with it
Datum plane and datum axis Where the datum feature symbol sits Offers “both planes” or “both axes”
Profile of a line and profile of a surface Two dimensional sections or the whole surface Treats the line control as a surface control
Overall flatness and per unit flatness Whole face or any small patch Adds the two values together
Runout reading and diameter High minus low on the indicator Halves or doubles the sweep
Regular and irregular feature of size Cylinder, sphere or parallel planes, or another shape Says only cylinders can be datums
Simultaneous and separate requirement Default or an explicit note Swaps which one needs the note

What is the difference between a datum plane and a datum axis?

The datum feature symbol is a framed letter on a leader. What it touches decides what it means.

Placed on the outline of a surface, on an extension line clear of the size dimension, or on a leader pointing at the surface, the datum feature is that surface and the datum derived from it is a plane. Aligned with the size dimension of a feature of size, or attached to its feature control frame, the datum is the centre feature: an axis for a bore, a centre plane for a width.

Two views side by side: symbol C on the outline of a flat face giving a datum plane, and symbol D aligned with the size dimension of a bore giving a datum axis
Placement of the symbol decides plane or axis. Illustration: CertCrafter, from GD & T Professional Certification, GDTP Y14.5 - ASME.

On a shop floor, this is a set-up decision. A face datum means the part sits on that face. An axis datum means the part is located by its bore, on a mandrel or an expanding pin. Misread one and the fixture holds the part wrong, then every position check that follows is measured from the wrong place.

The exam builds its wrong options from the same confusion. Expect “both establish an axis” for a symbol on a flat face, or “both establish a plane” for a bore. The correct reading is a plane from the face and an axis from the bore.

How do profile of a line and profile of a surface differ?

Profile of a line is a two dimensional control. At each cross section taken in the specified direction, the line element of the surface must lie within the zone, and every section is judged on its own. Nothing ties one section to the next. A rail with a curved top, toleranced with profile of a line | 0.3 | A | B, can twist or taper along its length without breaking the callout, because each section has its own zone, half the value each side of the true profile.

Profile of a surface is three dimensional. The whole surface must sit in one zone.

In industry practice this is a conversation with a supplier. An extruded part with a line profile callout is saying the cross section matters and the length does not. If the section-to-section relationship matters, the designer needs profile of a surface or an added form control. Inspectors who plot sections on a CMM and treat the result as a surface check pass parts the drawing never promised to control, or reject parts it allowed.

The trap in the exam is the option that says the callout controls the whole surface “exactly as profile of a surface would”. It does not. Watch for the option that invents a second envelope at twice the value, and for the one that claims a line profile cannot reference datums. It can.

What does a profile zone with no datum reference allow?

A profile of a surface with no datum feature references makes a zone that follows the true profile but is not tied to any datum reference frame. It controls the shape and the interrelationship of the surfaces within it and leaves the whole feature free to sit anywhere. With no unequal disposition stated, the zone is split evenly, half the value each side of the true profile.

Worked example: two walls of a slot

A slot is defined by a basic width, and both walls carry profile of a surface | 0.4 with no datum references. Ignoring form error within each wall, what widths does that allow?

  1. Split the zone: with no unequal disposition stated, the value is divided in two, half each side of the true profile.
  2. Each wall can move that half outward or inward, and there are two walls.
  3. Both outward: basic width plus half plus half, so basic plus the full zone value.
  4. Both inward: basic width minus half minus half, so basic minus the full zone value.

The width runs from basic minus the callout value to basic plus the callout value, a total variation of twice the callout value. Candidates who apply the split to one wall only get a range of one zone value in total. Candidates who give each wall the full value get a range twice as wide as the callout allows. Both are wrong, and both appear as options.

A black and white photograph of a designer at a drawing board with a telephone
Photo: Technical drawing, planning, designer, telephone Fortepan 19090 by FOTO:Fortepan — ID 19090: Adományozó/Donor: UVATERV. (Wikimedia Commons), CC BY-SA 3.0, via Wikimedia Commons.
Table of look-alike callouts: profile of a line 0.3 gives 0.15 each side, profile of a surface 0.4 gives 0.2 each side, two walls with basic 30.0 and profile 0.4 give 29.6 to 30.4, flatness 0.25 over 0.05 per 25 by 25 gives 0.25 for the whole face, circular runout is read as high minus low
Illustration: CertCrafter, from the ASME certification page and the sample questions. Illustration: CertCrafter, from GD & T Professional Certification, GDTP Y14.5 - ASME.

What is the difference between overall flatness and per unit flatness?

A two segment form callout gives a limit for the whole surface and a tighter one for any smaller area of a stated size. Take flatness | 0.25 over flatness | 0.05 / 25 x 25.

The first value is the total flatness allowed across the entire face. The second applies within every 25 by 25 area anywhere on that face. The face may wander gradually along its length while staying locally smooth.

The per unit value is a refinement inside the whole face zone. It is never added to it, so the two values do not sum. It does not let the inspector pick one convenient patch either: the requirement holds for every area of that size, including the worst one.

On a job, a sealing face or a ground reference surface often needs both. A gasket cares about the local patch, the assembly cares about the whole plane. The per unit segment can only tighten.

How is runout read, and why do people halve it?

Runout is full indicator movement: the total travel of the needle in one revolution, the highest reading minus the lowest. If the needle rises above zero by one amount and falls below zero by another, you add the two amounts. The result is then set against the number in the frame, as in circular runout | 0.04 | A-B.

Three slips fill the wrong options. The largest single reading ignores the low side and always understates runout. The difference of the two magnitudes subtracts as if both readings sat on the same side of zero. Doubling the movement assumes a diameter reading needs converting. The indicator already reads the full variation of the surface.

Where the indicator was zeroed makes no difference, because only the total travel counts. Zero it on the high point and the needle then only falls, so the runout is simply how far it fell. Circular runout is checked at a single cross section. A common datum A-B means both journals are simulated together to give one axis.

Where else do look-alike terms show up?

A feature of size has a size you can measure, such as a bore or a slot. A regular one is a cylinder, a sphere or a pair of parallel planes. An irregular one is a directly toleranced feature, or a collection of features, that can contain or be contained by an actual mating envelope other than those three. A moulded contour defined wholly by basic dimensions and controlled by profile is irregular, and it can be a datum feature. So a callout that labels such a contour as datum feature B is legal, and “only a cylinder, a sphere or a width may be a datum feature” is the trap answer.

Two hole patterns that share identical datum references, in the same order and with the same modifiers, are one simultaneous requirement by default. Writing SEP REQT beneath the frames breaks that default so each pattern is verified in its own reference frame. The exam swaps the two notations: simultaneous is the default and needs no note, separate is the exception that must be stated.

Last, a dated pair. Y14.5-2018 removed concentricity and symmetry as tolerance types. They appear on the exam only as wrong options or in questions about what replaced them. The 78% pass mark that circulates is from the older Y14.5-2009 exam; the 2018 Technologist exam is passed at 74%.

How do you study term pairs?

Write each pair on one card with the one-word difference underlined. Then say a callout aloud as a sentence before you answer anything about it. Ask what the symbol touches, whether the control is a section or a surface, and whether the number is for the whole or for a patch.

Try the free sample on the quiz page first. For the full set there is the practice test bundle with six tests, the certification guide, and the hub of guides. Two earlier posts pair well with this one: what the rules and symbology section tests and the ten most common mistakes.

Your next step: pick three callouts from a drawing at your own desk and write down, for each, whether the datum is a plane or an axis and what the number applies to.

Try these free questions

  1. An extruded rail has a curved upper surface controlled by `profile of a line | 0.3 | A | B`, with no other geometric control on that surface. A supplier asks how the surface will be evaluated. What does the callout control?

    1. Each cross section on its own within a 0.3 wide zone, leaving section to section variation free.
    2. The whole surface within a 0.3 wide three dimensional zone, exactly as profile of a surface would.
    3. Each cross section within a 0.3 wide zone and the surface within a 0.6 wide outer envelope.
    4. Only the size of the curved surface, a line profile being unable to reference datum features.
    Show the answer and explanation

    Answer: A. Profile of a line is a two dimensional control. At each cross section taken in the specified direction, the line element of the surface must lie within a zone 0.3 wide, 0.15 each side of the true profile, and datums A and B locate and orient that zone. Every section is judged on its own, so nothing in the callout ties one section to the next and the rail may twist or taper along its length without violating the tolerance. Option two turns the control into profile of a surface, which is the very distinction the line profile symbol exists to draw. Option three invents a second envelope at twice the value, which the standard does not provide. Option four confuses profile with a size control and denies datum references that are plainly present. If section to section relationship matters on this rail, profile of a surface or an added form control is the right addition.

  2. The ground face of a surface plate stand carries a two segment form callout, `flatness | 0.25` over `flatness | 0.05 / 25 x 25`. A production engineer asks what the pair of values requires of the finished face. What do they require?

    1. Flatness of 0.05 across the whole face, with 0.25 permitted inside each 25 by 25 area.
    2. Flatness of 0.25 across the whole face, and no more than 0.05 within any 25 by 25 area.
    3. Flatness of 0.30 across the whole face, the two stated values being added together.
    4. Flatness of 0.25 across the whole face, and 0.05 in one 25 by 25 area chosen at inspection.
    Show the answer and explanation

    Answer: B. A two segment form callout of this kind gives a limit for the whole surface and a tighter limit for any smaller area of the stated size. The 0.25 is the total flatness permitted across the entire face, and the 0.05 applies within every 25 by 25 area anywhere on that face, so the face may waver gradually along its length while remaining locally smooth. Option one swaps the two values, which would allow more variation in a small patch than across the whole surface and make the overall limit meaningless. Option three adds the numbers, but the per unit value is a refinement lying inside the overall zone and is never added to it. Option four lets the inspector nominate a single patch, whereas the requirement holds for every area of that size that can be laid anywhere on the face, including the worst one. The per unit segment can only tighten, never relax.

Take the full free 10-question sample with scoring →

Frequently asked questions

Which GD&T terms do ASME GDTP candidates confuse most?

Datum plane against datum axis, profile of a line against profile of a surface, and full indicator movement against a halved or doubled reading. Each pair differs by one word in the stem, so the options are built around the slip.

Does a datum feature symbol always give a plane?

No. On the outline of a surface, on an extension line clear of the size dimension or on a leader to the surface, it gives a plane. Aligned with a size dimension, it gives the centre feature: an axis for a bore, a centre plane for a width.

Does the per unit value in a two segment flatness callout add to the whole face value?

No. The first value is the limit for the whole face and the second applies within every area of the stated size. The per unit value only tightens the overall zone and is never added to it.

Official sources

  1. GD & T Professional Certification, GDTP Y14.5 - ASME — accessed 21 October 2026

Exam rules change. Check the awarding body's official page before you apply. CertCrafter is independent and is not affiliated with or endorsed by any awarding body.

Was this helpful?

Comments